RESIDENTIAL HVAC / TECHNICAL REFERENCE

Cooling starts with the right specifications.

Size room air conditioners, compare ductless architectures, and match cooling loads to the opening and electrical supply.

13Interactive tools
9Technical directories
USResidential standards

Residential cooling system / load map

Select a system or load point to open its calculator

01 / INTERACTIVE WORKSPACE

Choose your calculation

From room cooling capacity to electrical and seasonal energy requirements.

All calculators →
01 / Sizing

Air Conditioner BTU & Room Size Calculator

Room cooling demand from area, envelope and internal heat gains.

Open calculator ↗
Room envelope and cooling loadRoom thermal envelope420 sq ft8 ftNormal sunEnvelope × 12 occupantsBaseline 10,000 · adjusted 10,000 BTU/hBaseline / envelope / internal & leakage gains10,000 BTU/h tier
02 / Zone design

Mini-Split Zone & System Capacity Calculator

Connected capacity, simultaneous output and minimum turndown.

Open calculator ↗
Mini-split connected capacityOutdoor / indoor capacity pairing24,000BTU/h outdoorZ1 · 12,000 BTU/hZ2 · 9,000 BTU/hZ3 · 9,000 BTU/hConnected ratio: 125%80–100% target · 100–130% shared output · >130% high
03 / Mounting

Window Air Conditioner & Wall Sleeve Fit Calculator

Opening clearance, chassis geometry and outdoor airflow.

Open calculator ↗
Window fit and louver clearanceFront opening / side section28 in opening6 in total marginInsideOutside¼ in pitchInstallation range: neededSill / sleeve: 6 in · chassis 20 inStandard sill & side airflow
04 / Electrical

Air Conditioner Electricity, Amps & Cost Calculator

Running watts, power factor, circuit limits and monthly energy.

Open calculator ↗
Branch load versus current limitsBranch circuit load15 A breaker1 AOther load9.45 A · PF 0.92Combined current: 10.45 A50%80%100%Shared AC cap 7.5 A12 A continuous
05 / Units

BTU, Tons & Watts Converter

Convert thermal capacity, electrical input and portable ratings.

Open calculator ↗
Capacity and electrical equivalenceThermal output vs electrical inputCooling output3.5 kWElectrical input1 kWUse labeled DOE SACCLegacy ASHRAE: 14,000 BTU/hDual-hose / unknown configuration
06 / Efficiency

SEER2 & CEER Energy Savings Calculator

Compare annual energy and ten-year utility savings.

Open calculator ↗
Ten-year cumulative utility savingsTen-year cumulative utility savingsUSD00134.42.5268.85403.27.5537.610YearsCumulative savings
07 / Heating

Heat Pump Sizing & Low-Temperature Capacity Calculator

Heating delivery, demand and thermal balance point.

Open calculator ↗
Heat pump capacity / heating demandHeat pump capacity / heating demandBTU/h0-106,000512,0002018,0003524,00050Outdoor °FHeat pump outputBuilding demand15.3°F balance
08 / Energy

AC Operating Cost Calculator

Seasonal cooling and delivered heating utility costs.

Open calculator ↗
Cooling energy and utility comparisonSeasonal cooling comparisonFixed-speed energy806.4 kWhInverter energy537.6 kWhFixed-speed bill129 USDInverter bill86 USD
09 / Backup

AC Backup Power Calculator

Generator starting load and battery runtime.

Open calculator ↗
Generator running and surge marginGenerator power marginRequired running1,200 WRated running2,000 WRequired startup3,200 WRated surge3,500 W
10 / Workshop

Garage AC BTU Calculator

Garage cooling load, door leakage and workshop equipment.

Open calculator ↗
Garage load sectionGarage heat-gain section528 sq ft9 ftWest sunEnvelope × 1.15Door +1,500500 WBaseline 12,000 · adjusted 19,904 BTU/hBaseline / envelope / internal gains24,000 BTU/h tier230V class / multiple zones
11 / Sizing

AC Tonnage Calculator

Calculate room AC tonnage from floor area, ceiling height, sun exposure, insulation and internal gains, with the matching BTU/h capacity tier.

Open calculator ↗
Room envelope and cooling loadRoom thermal envelope420 sq ft8 ftNormal sunEnvelope × 12 occupantsBaseline 10,000 · adjusted 10,000 BTU/hBaseline / envelope / internal & leakage gains10,000 BTU/h tier
12 / Heating

BTU Heating Calculator

Estimate room heating BTU/h and thermal kW from winter design temperatures, envelope U-values and air exchange, then size a ductless heat pump.

Open calculator ↗
Room winter heat loss by componentPositive heat loss by componentWalls1,152 BTU/hWindows1,000 BTU/hDoors0 BTU/hCeiling1,050 BTU/hFloor1,680 BTU/hOutdoor air1,512 BTU/h
13 / Airflow

Room CFM Calculator

Calculate room CFM from dimensions and air changes per hour, convert AC BTU/h to airflow, and size an evaporative cooler.

Open calculator ↗
Room volume and airflowRoom airflow20 × 21 × 8 ft3,360 cu ft336 CFM6 ACH

02 / TROUBLESHOOTING

Start with the symptom

Trace cooling, airflow and electrical faults to the physical system.

All problem guides →
Service boundaries

EPA 608-certified HVAC technicians handle pressurized refrigerant circuits. Licensed electricians establish branch-circuit and hardwired supply requirements. Original appliance cords connect directly to compatible wall receptacles.

03 / DESIGN DECISIONS

Compare architectures

Identify the operating, mounting and electrical distinctions that matter.

All comparisons →
Window ACConditioned roomOutsideWindow opening / outdoor heat rejection
Portable ACConditioned roomOutsideExhaust to outdoors

Window AC vs. Portable AC

Compare →
Window ACConditioned roomOutsideWindow opening / outdoor heat rejection
Mini SplitConditioned roomOutsideSeparate outdoor condenser

Window AC vs. Ductless Mini-Split

Compare →
Window ACConditioned roomOutsideWindow opening / outdoor heat rejection
Through The Wall ACConditioned roomOutsideWall sleeve / rear heat rejection

Window AC vs. Through-the-Wall AC

Compare →
Single HoseConditioned roomOutsideExhaust to outdoors
Dual Hose Portable ACConditioned roomOutsideSeparate intake / exhaust

Single-Hose vs. Dual-Hose Portable Air Conditioners

Compare →
InverterCompressor output profileOutputTimeModulated compressor speed
Fixed Speed Air ConditionerCompressor output profileOutputTimeOn / off cycling

Inverter vs. Fixed-Speed Air Conditioners

Compare →
Dedicated CircuitBranch load arrangementBreakerBranch ratingNameplate and branch rating govern
Shared CircuitBranch load arrangementBreakerBranch ratingOtherAC cap: 50% of breaker

Dedicated Circuit vs. Shared Circuit for a 115V Room Air Conditioner

Compare →
ASHRAEASHRAE rating basisGross cooling capacityExhaust / infiltration losses
DOE SACCDOE SACC rating basisNet room cooling capacityIncludes portable heat losses

ASHRAE vs. DOE SACC Portable AC Capacity Ratings

Compare →
Single-zone mini-splitConditioned roomOutsideSeparate outdoor condenser
Direct port topologyDirect port topologyOutdoor unitIndoor 1Indoor 2Indoor 3Separate line sets from outdoor ports

Single-Zone vs. Multi-Zone Mini-Split Systems

Compare →

04 / ENGINEERING CONSTANTS

Reference the physical limits

One set of thermal, mounting and electrical reference values across the library.

Reference tables →

05 / TECHNICAL LIBRARY

Engineering reference directories

Browse the complete specification tree by topic.